Radial blowers with stainless steel housing
As the name suggests, the installation and operation conditions represent high demands,this product range sets an example. The laser welded stainless steel housing made from1.4301 are particularly resistant against many different chemicals and other aggressivesubstances. It can also be applied in such areas where corrosion protection is required and there are eventechnical solutions for high media temperatures.
Up to 180 m³/min and 10,000 Pa. Housing made of steel or stainless steel, impellers primarily bent backwards and made of stainless steel or aluminium. In stainless steel execution: Niro-shaft and maximum corrosion-resistance. Variable connection possibilities.
Up to 40 m³/min and 16,300 Pa. Wear-free, direct drive via offset frequency converter (FU/FC). Accelerates up to 200 Hz (approx. 12,000 rpm). Housing made of steel or stainless steel, impellers bent backwards and made of high-tensile QSTE steel, hybrid bearing, corrosion-resistant. Variable connection possibilities.
Up to 500 m³/min and 4,500 Pa. Highly efficient impellers bent backwards and made of steel. Very high level of effectiveness, low energy consumption. Housing made of steel. Variable connection possibilities.
Up to 400,000 m³/h (6,700 m³/min) and 8,000 Pa. With direct, coupling or belt drive - frequency converter operation also possible. Housing and impellers with blades bent backwards and made of steel or stainless steel. Variable connection possibilities. Fans of this type series are always configured specific to the project.
Up to 360,000 m³/h (6,000 m³/min) and 17,500 Pa. With direct, coupling or belt drive - frequency converter operation also possible. Housing and impellers with blades bent backwards and made of steel or stainless steel. Variable connection possibilities. Fans of this type series are always configured specific to the project.
Up to 400,000 m³/h (6,700 m³/min) and 30,000 Pa. With direct, coupling or belt drive - frequency converter operation also possible. Housing and impellers with blades bent backwards and made of steel or stainless steel. Variable connection possibilities. Fans of this type series are always configured specific to the project.
Up to 175,000 m³/h (2,900 m³/min) and 35,000 Pa. With direct, coupling or belt drive - frequency converter operation also possible. Housing and transport impellers with blades bent backwards and made of steel or stainless steel. Variable connection possibilities. Fans of this type series are always configured specific to the project.
Up to 580,000 m³/h (9,700 m³/min) and 2,700 Pa. Suction on both sides. With coupling or belt drive - frequency converter operation also possible. Housing and impellers with blades bent backwards and made of steel or stainless steel. Variable connection possibilities. Fans of this type series are always configured specific to the project.
Up to 95 m³/min and 2,200 Pa. Explosion-proof construction according to DIN EN 14986 (Design of fans working in potentially explosive atmospheres). Suitable for zones 1, 2 and 22. Housing made of cast aluminium, drum impellers bent forward and made of stainless steel, mostly corrosion-resistant.
Up to 90 m³/min and 6,800 Pa. Explosion-proof construction according to DIN EN 14986 (Design of fans working in potentially explosive atmospheres). Suitable for zones 1, 2 and 22. Housing made of cast aluminium, impellers primarily bent backwards and made of aluminium, mostly corrosion-resistant.
Up to 97 m³/min and 16,000 Pa. Explosion-proof construction according to DIN EN 14986 (Design of fans working in potentially explosive atmospheres). Suitable for zones 1, 2 and 22. Wear-free, direct drive via offset frequency converter (FU/FC). Higher rotation up to 105 Hz (approx. 6,200 rpm). Pressure-proof encapsulated motor. Housing made of cast aluminium, impellers primarily bent backwards and made of aluminium, mostly corrosion-resistant.